Indicative onlyThese tools provide indicative calculations only. No warranty is given as to the accuracy, completeness or fitness for purpose of any output. Using this site does not create a professional relationship or duty of care between brickdims and the user. Results must not be used as a substitute for professional advice, site-specific assessment, or formal compliance sign-off. Building regulations are subject to change, so always verify against the current editions of the relevant Approved Documents and consult a building control officer where required. brickdims accepts no liability for any loss, damage or non-compliance arising from reliance on these tools, to the fullest extent permitted by law. If any part of these terms is found unenforceable, the remaining terms continue to apply. These terms are governed by the laws of England and Wales. By using this site you accept these terms.

U-value
calculatorBETA

Calculate the U-value of a wall, roof, or floor from individual material layers.

Results from brickdims.com tools are indicative only. Using this site does not create a professional relationship or duty of care. Not a substitute for professional advice or formal compliance sign-off.

Wall U-value

RseRsiEXTERIORINTERIOR0°7°14°21°
01.5
0.222
W/m²K
Rse (exterior surface)0.04
Σ R (layers)4.32
Rsi (interior surface)0.13
Rtotal4.49
This result is indicative only. Accuracy depends on inputs provided. Results are not a substitute for a certified assessment using approved methods.

Wall layers, exterior to interior

MaterialThicknessR-value
mm
0.013
mm
0.133
mm
0.18 (fixed)
mm
3.030
mm
0.909
mm
0.060
Total377.5 mm4.495
Drag to reorder. R = thickness ÷ λ

Material library

Materialλ W/(mK)
Clay brick, outer leaf0.77
Clay brick, inner leaf0.56
Mortar, outer leaf0.94
Mortar, inner leaf0.88
Engineering brick (1.0–1.7 by type)1.3
Concrete (dense, 2200 kg/m³)1.65
Concrete (lightweight)0.38
Limestone1.5
Granite2.9
Dense aggregate block1.13
Aerated concrete block0.11
Softwood timber0.13
Hardwood timber0.18
Plywood0.13
OSB / chipboard0.13
Chipboard flooring0.13
Timber floorboards0.14
Mineral wool (0.033–0.044)0.033
Glass wool (0.033–0.044)0.033
Rigid PIR / PUR0.022
Rigid EPS0.038
Rigid XPS0.034
Phenolic foam0.019
Wood fibre (rigid)0.042
Wood fibre (flexible)0.05
Cellulose (blown)0.04
Sheep wool (0.035–0.040)0.038
Hemp / flax batts0.04
Cork board0.04
Aerogel blanket (0.013–0.018)0.015
Vacuum insulation panel (0.007–0.010)0.008
Unventilated air cavity (R = 0.18 fixed)R 0.18 fixed
Well-ventilated cavity (R = 0, see note)R 0 fixed
Plasterboard (standard, ≤700 kg/m³)0.21
Plasterboard (high density, ≤900 kg/m³)0.25
Sand / cement render1
Dense gypsum plaster0.57
Lightweight / perlite plaster0.18
Ceramic tiles1.3
Sand / cement screed0.41
Carpet and underlay0.06
Vinyl / linoleum0.17
Clay roof tiles1
Concrete roof tiles1.5
Natural slate2
Roofing felt / underlay0.23
Sarking board0.13
Profiled metal deck50
Built-up felt (3 layer)0.23
Vapour control layer0.23
Hardcore / gravel0.36
Sand blinding0.3
DPM (polythene)0.23
Reinforced concrete slab (2% steel)2.3
Beam and block floor1.13
Clay / subsoil (0.9–1.8)1.5
Click any row to add as a layer. R = thickness ÷ λ for standard materials. Cavity R-values are fixed per BS EN ISO 6946 Table 2: unventilated cavity ≥25mm gives R = 0.18 m²K/W. Well-ventilated cavities eliminate the resistance of the cavity and all layers between it and the external surface; model only the layers on the room side.
λ values shown are typical design values based on BS EN ISO 10456. Manufacturer declared values (from product test certificates) will often differ and should be used where available for accurate results, particularly for insulation products.

R and U converter

U-value (W/m²K)
0.4000Calculated
U = 1/R. Surface resistances not included in this converter.

Benchmark comparison: indicative reference only

Part L limits shown for reference only. Always verify against the full Approved Document for your project.
  • Passivhaus ClassicReview
    0.222 W/m²K is above the 0.15 W/m²K figure. Passivhaus Institut, voluntary.
  • AECB SilverReview
    0.222 W/m²K is above the 0.2 W/m²K figure. AECB, voluntary.

Heat loss calculation

Temperature inputs affect the heat loss calculation only. The U-value and all benchmark comparisons are independent of temperature. Default values based on CIBSE Guide A UK design conditions for dwellings. Adjust for your project as required.
Heat flux
5.3 W/m²
Heat loss per square metre of this element
Enter element area above to calculate total heat loss.
ΔT = 24.0 K (21°C − -3°C)
This is a simplified steady-state calculation for a single element. It does not account for thermal bridging, air infiltration, or intermittent heating. For whole-building heat loss calculations, approved methodologies include SAP (for dwellings) and PHPP.
Lambda values from BS EN ISO 10456:2007. Surface resistances per BS EN ISO 6946:2017. Cavity air gap R-value is fixed at 0.18 m²K/W per BS EN ISO 6946 Table 2 (unventilated, ≥25mm); equivalent lambda shown is calibrated for 50mm; vary thickness with caution. AD L (para 4.1) states that U-values should be assessed using the methods and conventions in BRE BR 443.